Add to Cart
Product Features:
* High efficiency: efficient and energy saving;
* Modularity: modular UPS+Battery, extendibility;
* Intelligence, visibility: intelligent design of monitoring and management system;
* Isolation of internal & external module, anti-dust and dehumidification;
* Rapid deployment: no need engineering survey, plug and play, facilitates the operation with one
stope deployment;
* Environmental and energy management, Operation optimization, PUE maximum;
* Cloud computing: network connections management, parallel or multi-network;
* Precision cooling system, energy-saving: Precision cooling, central air condition needless, cost
reduction
* Standard cabinet: standard aluminium frame structure EIA-310-D, easy installation within 5
minutes
* All-in-one: Integrated of rack, air condition, UPS, PDU monitoring & on-site management system etc
| Module | HCS1006 | HCS1010 | HCS1015 | HCS8015 |
| System recoommended load power | 3.5kw | 7kw | 10.5kw | 3.5kw |
| Reommended input air-switch configuration | single-phase | single-phase | three-phase | single-phase |
| 100A | 125A | 80A | 100A | |
| Reommended input cable configuration | single-phase | single-phase | three-phase | single-phase |
| 16mm2 | 25mm2 | 10mm2 | 16mm2 | |
| Precision air conditioner | ||||
| Air conditioning form | split-type air conditioner | top rack air conditioner | ||
| Cooling capacity(kw) | 3.5 | 5 | 9 | 3.5 |
| Air column(m3/h) | 750 | 1100 | 1950 | 750 |
| Energy efficiency ratio | 3.7kw | |||
| Using environment | -45~50 ℃; 0%~90%RH | |||
| Indoor uint dimensions(W*D*H)mm | 440*750* 220(5U) | 440*750*440 | 600*1100*350 | |
| Outdoor uint dimensions(W*D*H)mm | 300*850*575 | 450*1200*700 | no outdoor unit | |
| Input power | 220V 50HZ | |||
| Airflow | Upflow/Downflow | Downflow | ||
| UPS | ||||
| Wiring | single phase in and single phase out | 3phase in and 1 phase out | 1 phase in and 1 phase out | |
| Capacity(KVA) | 6 | 10 | 15 | 6 |
| Input voltage range | 110 ~300VAC | 176 ~520VAC | 110-300VAC | |
| Power factor | ≥0.99 | |||
| Output voltage | 220/230/240VAC | |||
| Voltage accuracy | ± 1% | |||
| Frequency accuracy | 50/60HZ ± 0.1HZ | |||
| Power factor | 0.8 | |||
| Conversion time | 0ms | |||
| waveform distortion | Linear load ≤2%; non-linear load≤3% | |||
| Panel display | Load size, battery capacity, utility mode, battery mode, bypass mode, fault mode | |||
| Communication interface | Support RS232, RS485, SNMP card | |||
| W*D*H(mm) | 2U | 3U | 6U | 2U |
| Net weight(kg) | 12 | 16 | 45 | 12 |
| Battery | ||||
| Standard battery | 12V/7Ah | |||
| Backup time | Standard ≥10inch(long delay can be external battery) | |||
| Battery pack size | 2U | |||
| Power distribution model | ||||
| Function | Integrated input distribution, UPS output distribution | |||
| Way of communication | RS485 | |||
| Specification | 3U | 6U | 3U | |
| HMI | ||||
| Temperature and humidity detection port | SUPORT | |||
| Way of communication | Support RS232, RS485, TCP/IP protocol | |||
| Display screen | 10inch touch color screen | |||
| PDU | ||||
| Input current | Single phase 16A | |||
| Out bits | 12-bit 10A Universal socket | |||
| Installation method | Vertical installation | |||
| Communication display | Digital display, RS485 communication | |||
| Configuration type | One piece per cabinet | |||
| KVM | ||||
| Visual area | 17inch | |||
| Configuration | Optional | |||
| Cabinet | ||||
| Function | ||||
| Single cabinet size(W*D*H)mm | 600*1100*2000 | |||
| Cabinet configuration | Single cabinet | Two cabinets | Three Cabinets | Single cabinet |
| Load(kg) | 1500 | |||
| Environmental monitoring | ||||
| Temperature and humidity | Support | |||
| Leakage | Support | |||
| Smoke | Suport | |||
| Fire Module(Optional) | 1U height(1 set per cabinet) | |||